Archives

TP-L Series On-line Thermal Imaging Sensor

 

TP-L

The TP-L Series is acompact Infrared Thermo Imaging/Radiometric Camera, utilizing a lowcost, high sensitivity, thermopile array detector. This CHINO developed detector allows the camera tomeasure real time temperature (RadiometricOperation) and provide zone alarms. Ethernet connectivity allows thecamera to communicate with a PC running CHINO Imaging Software or customer’s LAN network.

.

Upto 4 sensors can be connected to a PC via LAN running the CHINO ViewerSoftware, which allows you to monitor thermal images, measure temperature andprovide an alarm.

TP-L2-eng

Theunit can be used as a stand-alone (not connected to PC software) areatemperature alarm sensor, which provides 2 Mos-Fet contacts and stores AlarmImage in Camera/Sensor.

TP-L3-eng

APPLICATIONS:

Monitor & Alarmon Hot Spots for boiler and furnace skin temperature

TP-L1

Predictive maintenance on motors & pump/motorbearings

TP-L2

Inspect heating areas onvehicles

TP-L4-eng

Monitor hot spots on transformer/distribution panels, in Electric Utilities and Control Rooms

TP-L3

Security monitoring for vehicles, people and animals

TP-L4

DOWNLOAD PDF

IR-R SERIES BLACKBODY FURNACES

IR-R_01

NRLM type comparison blackbody furnaces, which have been jointly developed with the National Research Laboratory of Metrology, are large opening blackbody furnaces for calibration of radiation thermometers, and a high temperature comparison blackbody furnace uses a standard radiation thermometer for comparison calibration.NRLM Type Comparison Blackbody Furnace.

FEATURES

  • The cavity is profiled as a double cone and the high emissivity is realized with a large opening.
  • For low temperature, a platinum resistance thermometer (sold separately) is used as a standard thermometer.
  • For medium temperature, a 0.9µm standard radiation thermometer (sold separately) is used for comparison calibration.
  • Long-term stability

IR-RST STANDARD INFRARED RADIATION THERMOMETER

IR-RST_01

The IR-RST series is single-color radiation thermometers that are used as the standard unit for comparison calibration of radiation thermometers by using comparison blackbody furnaces.

FEATURES

  • 2 kinds of measuring wavelength of 0.65µm and 0.90µm are available.
  • With an official certificate (JCSS calibration certificate)

C-800 SERIES STANDARD THERMOCOUPLES

C-800 The R800 series is standard thermocouples for calibration of thermocouples. Three types of S type thermocouple, R type thermocouple, and B type thermocouple are available. The temperature-thermal EMF table is prepared on request.

R-800 SERIES STANDARD PLATINUM RESISTANCE THERMOMETERS

R-800_01

The R800 series standard platinum resistance thermometers conforming to the International Temperature Scale, 1990 (ITS-90) have been commercialized under the guidance of the National Research Laboratory of Metrology.

FEATURES

  • The thermometers cover from vapor point of helium to freezing point of silver.
  • Various models are prepared for low temperature and high temperature.
  • Fixed point calibration and precision comparison calibration are available.

 

 

JS – JT SERIES THYRISTOR REGULATOR

JS_JT_01

The JS/JT series is small and lightweight thyristor regulators with built-in firing unit for high density of mounting on instrumentation panels.

FEATURES

  • Wide selection from 10A to 1000A on both single-phase and three-phase load applications
  • Two control systems of phase-angle firing system and zero-cross firing system
  • 4 kinds of feedback type of voltage feedback, current feedback, power feedback and without feedback are available in accordance with the characteristics of heating element on the phase-angle firing system
  • Two kinds of zero-cross firing system, conventional type and modulation type, are available for sensitive power control
  • Protection functions including thyristor gate-off and rapid fuse are built-in.

DOWNLOAD PDF

JU SERIES THYRISTOR REGULATOR

JU_01

The JU series small and lightweight thyristor regulators for single-phase loads are characterized with high panel installation density.
Two control systems, a phase-angle firing system and a zero-cross firing system, are built in and can be changed by remote contacts signal.

FEATURES

  • Compact structure
    Compact, lightweight and high panel installation density
  • Options
    The options of heater disconnection alarm function and current limit function are available.
  • Phase-angle firing/zero-cross firing
    The phase-angle firing system and the zero-cross firing system are selectable. The running by the phase-angle firing system at the initial stage and by the zero-cross firing system at the normal stage is possible.
  • Zero-cross firing system
    With the delta-sigma modulation, which controls every 1 cycle, the fine control like the phase-angle firing system is possible.
  • Setting unit (option)
    Display of various parameters, voltage/current/ power and change of the feedback system are possible.
  • Various protections functions built-in
    The thyristor element is protected by melting of the rapid fuse for short-circuit of load, and by gate-off for over-current. For models with a cooling fan built-in, alarm is activated and output is stopped for abnormal heat-sink temperature.
  • Self-diagnosis function built-in
    The self-diagnosis function is built in for abnormal operation, abnormal thyristor element and abnormal power supply.

DOWNLOAD PDF

JB SERIES THYRISTOR REGULATOR

JB_01

The JB series small and lightweight thyristor regulators for single-phase loads are characterized with high panel installation density.
6-models from 10A rated current to 100A rated current are available.
Two control systems, a phase-angle firing system and a zero-cross firing system, are built.

FEATURES

  • Compact and standalone, mounting space-saving, easy wiring
  • Phase-angle firing/zero-cross firing can be selected according to applications, power source environment, etc.
  • Soft-start, soft-up/down and soft-start at power failure recovery for precise control
  • Automatic frequency judgment function, ramp setting function and low limit setting function are built-in.

DOWNLOAD PDF

MR 2041 FOUR CHANNEL HANDY LOGGER

mr2041

Handy logger MR2041 is a palm size data logger, it capable to store up to 10000 temperature data per each channel.
Power supply of logger is selectable from AA battery or AC adaptor, so it is usable as a portable type logger or fixing type logger.
Using the exclusive software, recording/recalling of data and  programming of logging parameters can be executed with logger or through a personal computer.

FEATURES

  • Input signals: thermocouple K, E, J, T,0 to 5V; 0 to 20mA;
  • Simultaneous 4 channels, measurement and display.
  • High/low alarms for each channel.
  • Calculation function: maximum / minimum/ average.
  • Logging method: log mode and tag-mode.
  • Data process-able through a personal computer.
  • IP 64 dust tight and splash proof enclosure.
  • AA battery supply.

APPLICATIONS

  • Logging and storing data in research and laboratories
  • Calorimetric measurement
  • Temperature monitoring for HACCP, ISO
  • Control industrial process
  • Temperature monitoring for production line
  • Temperature monitoring in food transportation

DOWNLOAD PDF

HN-CH PALM SIZED TEMPERATURE HUMIDITY METERS

NH_CH_01

The HN-CH series is reliable and accurate palm-sized temperature/ humidity meter with the measuring humidity range of 0 to 100%RH by using a new developed humidity sensor.
It also provides the data logging function capable to store each 8000 readings of temperature and humidity into memory.

FEATURES

  • Excellent reproducibility and reliability by capacitance type humidity sensor
  • Humidity sensor with quick response in 15 seconds 
    Easy maintenance by complete interchangeable sensors
  • Handheld type, desktop type and wall-mounting type are available for various applications.
  • Data logging function capable to store each 8000 readings of temperature and humidity into memory
  • The sensor used in probe type and separated type can be used in temperature from -40 to 80°C.
  • With RS-232C or RS-485 communications interface
  • A software package for analyzing data is available.
  • Power supply of AA alkaline batteries or through AC adapter

DOWNLOAD PDF